1. The sign must be charged for a minimum of 60 minutes to become fully operational.
2. External
illumination source must be supplied by a circuit not controlled by an automatic timer or sensor and whose controls are accessible
only to authorized personnel.
3.
External illumination source is to be energized at all times during building occupancy.
4. Lighting levels on the sign
face(s) should be confirmed after any change in external lighting.
5. It is recommended that inspections be performed
in accordance with applicable codes.
6. Install sign indoors only, where not exposed to direct sunlight, moisture or temperatures
outside the range of +10 degree to 40 C (50-104 F).
ExitGlo exit signs can be used as a primary or secondary exit sign in accordance with the UL924 standard
for "Emergency Lighting and Power Equipment", Eighth Edition, July 2001 revisions. Install in compliance with NFPA
Life Safety Code 101 or other applicaple buiding or fire codes for photoluminescent exit signs. They are non-explosive, non-corrosive,non-toxic,
non-radioactive and non-electric, requiring no electrical wiring or batteries.